Actively Exploited, CISA KEV

CVE-2026-83549: SonicWall SMA1000 Appliances High-Severity Vulnerability

Severity: High | CVSS 3.1: 7.8 | Published: 2026-09-01 | KEV Added: 2026-09-02

What is CVE-2026-83549?

Post-authentication Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability has been identified in the SMA1000 Appliance Management Console (AMC) which in specific conditions could potentially enable a remote authenticated attacker as administrator to execute arbitrary OS commands, resulting in remote code execution.

Technical Analysis

Weakness Classification

This vulnerability is classified as CWE-78, OS Command Injection. The application passes untrusted input to an operating system shell command, enabling an attacker to execute arbitrary OS commands with the application's privileges.

Attack Vector Breakdown

  • Attack Vector: Local
  • Attack Complexity: Low
  • Privileges Required: Low
  • User Interaction: None
  • Scope: Unchanged
  • Confidentiality: High
  • Integrity: High
  • Availability: High

Impact Analysis

Exploitation requires local access to the target system, such as a local user session or a malicious file opened by a user. The attack complexity is low, meaning exploitation does not depend on specialized conditions or race windows. Successful exploitation can result in full confidentiality breach (complete data disclosure), complete integrity compromise (data modification or code execution), total availability loss (denial of service). The application passes untrusted input to an operating system shell command, enabling an attacker to execute arbitrary OS commands with the application's privileges.

Exploitation Probability (EPSS): 9.9% chance of exploitation in the next 30 days (96th percentile). While the base probability may appear low, inclusion in CISA KEV confirms real-world exploitation is already occurring.

Is CVE-2026-83549 being exploited?

Yes. CVE-2026-83549 is listed in CISA's Known Exploited Vulnerabilities (KEV) catalog, restricted to CVEs with confirmed active exploitation in the wild. CISA added this vulnerability on 2026-09-02. Inclusion in KEV triggers the patching mandate under BOD 22-01 for U.S. federal civilian agencies, with a remediation deadline of 2026-09-05.

How to fix CVE-2026-83549

Apply the security update issued by SonicWall for SMA1000 Appliances. Check the SonicWall Security Advisories page for the specific patch or update. If an immediate patch is not possible, consult the vendor advisory for mitigation guidance, restrict network exposure of the affected service, and monitor logs for indicators of exploitation. CISA's Known Exploited Vulnerabilities catalog requires U.S. federal agencies to remediate this vulnerability by the due date shown below under Binding Operational Directive 22-01. Private organizations should treat KEV entries as priority-one patches because active exploitation has been confirmed in the wild.

Related Vulnerabilities

Other actively exploited vulnerabilities affecting SMA1000 Appliances or sharing the same weakness (CWE-78):

  • CVE-2026-83548 (Critical 10.0) [same product], A Pre-authentication SSRF vulnerability exists in the SMA1000 Appliance Work…
  • CVE-2026-15409 (Critical 10.0) [same product], A Server-side request forgery (SSRF) vulnerability has been identified in the…
  • CVE-2026-15410 (High 7.2) [same product], Post-authentication improper control of generation of code ('Code Injection')…
  • CVE-2026-111560 (High 7.2) [same CWE], Improper neutralization of shell metacharacters in the timezone configuration…
  • CVE-2026-19868 (High 7.5) [same vendor], An authentication enforcement vulnerability in SonicOS SSLVPN service may…

Frequently asked questions

Is CVE-2026-83549 critical?

CVE-2026-83549 has a CVSS 3.1 base score of 7.8, High severity. It should be treated as a priority patch, especially given the active exploitation confirmed by CISA.

Is CVE-2026-83549 being actively exploited?

Yes, CISA added CVE-2026-83549 to the Known Exploited Vulnerabilities catalog on 2026-09-02. Inclusion in KEV means CISA has confirmed in-the-wild exploitation.

How do I patch CVE-2026-83549?

Apply the security update from SonicWall for SMA1000 Appliances. Federal agencies must remediate by 2026-09-05 under BOD 22-01. Refer to the SonicWall Security Advisories for the official patch.

What type of vulnerability is CVE-2026-83549?

CVE-2026-83549 is classified under CWE-78 (OS Command Injection). The application passes untrusted input to an operating system shell command, enabling an attacker to execute arbitrary OS commands with the application's privileges.

What is the CVSS score for CVE-2026-83549?

CVE-2026-83549 has a CVSS 3.1 base score of 7.8, classifying it as High severity. The attack vector is Local, attack complexity is Low, and non-zero privileges are required.